INSTRUCTION BULLETIN
2CT and 2CT-3 Pumpak for 145TC, 184TC and 215TC drive
OVERVIEW:
These instructions pertain to the assembly and
installation of a 2CT pump end. Your 2CT
pump may have included a driver such as close-
coupled electric motor, engine, bearing pedestal
or hydraulic motor pedestal that will hereafter be
referred to as the driver.
CAUTION.
2CT pumpaks are shipped
with no running clearance between the
impeller and housing. 2CT pumpak impeller
clearance can only be established after the
pumpak has been secured to the driver. See
Pumpak Assembly.
PUMPAK ASSEMBLY:
(pump end suitable
for mounting to various drivers).
1. Loosen the drive sleeve clamp.
2. Lightly coat the driver shaft with an anti-
seize compound.
3. Slide the pump onto the driver by hand.
This should not require extreme force.
4. Install and tighten fasteners (4) into the
pump adaptor securing the drive.
5. Tighten the drive sleeve clamp fastener to
20 to 26 foot pounds.
6. To establish impeller running clearance:
Loosen the two opposing nuts that fasten
the suction chamber to the pump. Loosen
the locknut of one of the three jackscrews.
Back-off the cleanout chamber by rotating
the jackscrew clockwise ½ turn then re-
tighten the locknut. Repeat this step for the
other two jackscrews. Re-tighten the
suction chamber fasteners.
7.
Rotate the shaft to ensure that the pump
rotates freely before putting the pump into
service.
INSTALLATION:
Optimum performance can be attained by
placing the pump as close to the liquid source as
possible. Secure the pump by mounting it to a
foundation or base plate.
Hose or pipe can be used on the suction and
discharge. The suction line must not be reduced
in size. If hose is used, reinforced non-
collapsible type is recommended. The discharge
line must be rated to the maximum pressure
developed by the pump.
Avoid kinks in the hose and unnecessary
restrictions that may affect pump performance.
All pipe connections must be sealed with
adequate thread sealant. A small air leak in the
suction line will affect priming performance. If
a throttling valve is used to adjust the flow rate,
it should be mounted to the discharge piping
only - never in the suction. A large low
restriction de-watering type strainer must be
used whenever solids larger than 1.25” spheres
are present in the liquid source.
OPERATION:
Fill the pump with liquid prior to starting
through a fitting on the discharge piping. The
pump housing should be completely full. If the
pump has a discharge valve it must be fully open
to expel air during priming at initial start-up.
Long horizontal suction lines require extra time
to prime, 2 additional minutes for every 10 feet
of horizontal run.
Start the pump driver. The pump will prime the
suction hose and establish flow in about 5
minutes, more or less, depending upon the lift
distance and length of horizontal run. After
prime, the pump will perform to its full flow
capability.
After the initial prime, the pump will retain
liquid in the housing and may not need to be
refilled after shutdown and restart even if the
suction pipe has air in it.